Experiment 1: a magnet and a coil
Faraday first moved a magnet in and out of a coil joined to a galvanometer. The needle kicked whenever the magnet moved, the other way when it moved back, and not at all when it was still. You can see this in the lesson on electromagnetic induction.
Experiment 2: a coil carrying a current
A coil carrying a steady current from a cell makes a field like a bar magnet’s. In the 3D model, choose A coil carrying a current and press Play.
- Move coil 1 towards coil 2: the needle on coil 2 kicks.
- Hold it still: nothing, even though coil 1 still carries its current.
- Move it away: a kick the other way.
Coil 1 does exactly what the magnet did. The two coils are separate circuits that never touch; only the changing magnetic field links them.
Experiment 3: switching on and off
Choose Switching on and off. Now both coils stay still.
- Press the key: as the current in coil 1 grows, its field through coil 2 grows, and the needle gives a brief kick.
- Hold it down: a steady current, and the needle returns to zero.
- Release the key: as the current dies, a kick the other way.
Then an iron rod is slid through both coils. The iron makes the field of coil 1 much stronger and guides it through coil 2, so the kicks are far bigger. This is the idea behind the transformer.
What they show
In every experiment, a current is induced in coil 2 only while the magnetic flux through it is changing, whatever causes the change: a moving magnet, a moving coil, or a changing current. The faster the change, the bigger the kick.
Worked example
Coil 2 has 50 turns. When the key in coil 1’s circuit is pressed, the flux through each turn of coil 2 rises from 0 to 3 × 10⁻⁴ Wb in 0.02 s, then stays steady. Find the average emf in coil 2 (a) while the current grows, (b) while it is steady.
- (a) 0.75 V.
- (b) The flux is not changing: 0 V.
Remember: Faraday showed that a moving magnet, a moving coil carrying a current, or switching a current on or off all induce a current in a nearby coil, but only while the flux through it is changing.
Formulas and where to use them
What all three share
- where
- magnetic flux through the coil (Wb)
Use it when: Every one of Faraday’s experiments.
Common mistakes
- Expecting a current while the key is held down. A steady current in coil 1, however big, induces nothing in coil 2.
- Thinking the coils must touch. They are separate circuits; only the changing magnetic field links them.
- Forgetting the direction. Switching on and switching off give kicks in opposite directions.
Quick check
Test yourself — pick an answer to see if you got it.
1. With the key held down and a steady current in coil 1, the galvanometer on coil 2 reads…
The flux through coil 2 is not changing.
2. Switching the current in coil 1 off makes the needle on coil 2…
The flux now falls instead of rising.
3. An iron rod through both coils makes the kicks…
The iron greatly increases the flux through coil 2.
4. A coil carrying a steady current is moved towards a second coil. A current is induced because…
It acts like a moving magnet.
5. Coil 2 has 50 turns. When the key is pressed, the flux through each turn rises from 0 to 3 × 10⁻⁴ Wb in 0.02 s. The average emf is…
.