One coil inducing another
When the current in one coil changes, its changing flux passes through any coil nearby and induces an emf there. This is mutual induction. Faraday saw it when he switched the current in one coil on and off.
The emf in coil 2 is proportional to the rate of change of the current in coil 1:
M is the mutual inductance of the pair, measured in henry, the subject of the next lesson.
Near, far and turned
In the 3D model, choose Near, far and turned and press Play. Coil 1 carries an alternating current, so its flux keeps changing. Coil 2 has a galvanometer.
- Close and in line: most of coil 1’s flux passes through coil 2, and its needle swings widely to and fro.
- Further away: less of the flux reaches coil 2, and the swings are much smaller.
- Close but turned at right angles: coil 1’s field now runs across coil 2’s turns instead of through them. Almost no flux links it, and the needle hardly moves.
How much mutual induction there is depends on how much of one coil’s flux passes through the other.
A shared iron core
Choose A shared iron core. Both coils are wound on one iron core. The iron guides nearly all of coil 1’s flux through coil 2, and the swings are the biggest yet.
Uses, and a nuisance
- Transformers: two coils on one core; an alternating current in one induces an alternating emf in the other, stepped up or down.
- Wireless chargers for phones and toothbrushes: a coil in the pad induces a current in a coil in the device, across a small gap.
- Induction cookers: a coil induces currents in the pan.
Mutual induction can also be a nuisance: changing currents in one circuit can induce unwanted signals in another nearby.
Worked example
Two coils have a mutual inductance of 0.02 H. The current in coil 1 rises steadily from 0 to 5 A in 0.1 s. Find the emf induced in coil 2 (a) while it rises, (b) once it is steady at 5 A.
- (a) A/s, so 1 V.
- (b) A steady current: 0 V.
Remember: a changing current in one coil induces an emf in a nearby coil; more when they are close, in line or share an iron core; transformers and wireless chargers work this way.
Formulas and where to use them
Mutually induced emf
- where
- mutual inductance of the two coils (H)
- rate of change of current in coil 1 (A/s)
Use it when: Any two coils whose fluxes link.
Common mistakes
- Expecting an emf from a steady current. The current in coil 1 must be changing; that is why transformers use alternating current.
- Thinking the coils must be wired together. Only their magnetic flux links them.
- Forgetting alignment. Coils at right angles link almost no flux, however close they are.
Quick check
Test yourself — pick an answer to see if you got it.
1. Mutual induction is an emf induced in a coil by…
The flux of coil 1 changes through coil 2.
2. Two coils are close together, with their axes at right angles. The mutual induction is…
Little of coil 1’s flux passes through coil 2.
3. Putting both coils on one iron core makes the induced emf…
The iron guides the flux through both.
4. Two coils have M = 0.02 H. The current in coil 1 rises at 50 A/s. The emf in coil 2 is…
.
5. Which of these works by mutual induction?
Two coils on one core.