How much field passes through
Faraday’s experiments show that what matters is how much magnetic field passes through a coil. We measure this with the magnetic flux Φ. A good picture: Φ is like the number of field lines passing through the loop.
For a flat loop of area A in a uniform field B:
Here is a vector of size A along the normal to the loop, and θ is the angle between the field and the normal. Flux is a scalar. Its unit is the weber: .
Turning the loop
In the 3D model, choose Turning the loop and press Play. A loop of area 0.02 m² sits in a uniform field of 0.4 T.
| θ | Φ |
|---|---|
| 0° (facing the field) | Wb |
| 60° | Wb |
| 90° (edge on) | 0 |
As the loop turns, its area stays the same, but seen from along the field it looks narrower, and fewer field lines get through. Edge on, none pass through at all.
More field, more area
Choose More field, more area. Facing the field, make B twice as strong: the lines are twice as crowded and twice as many pass through. Or give the loop twice the area: again twice the flux. Field, area and angle all count.
For a coil of N turns, each turn is linked by Φ, so the total flux linkage is .
Worked example
A circular loop of radius 5 cm is in a uniform field of 0.5 T, with its normal at 30° to the field. Find the flux through it.
- m².
- 3.4 × 10⁻³ Wb.
Remember: , with θ from the normal; largest facing the field, zero edge on; measured in weber, 1 Wb = 1 T m².
Formulas and where to use them
Magnetic flux
- where
- magnetic flux (Wb)
- magnetic field (T)
- area of the loop (m²)
- angle between B and the normal to the loop
Use it when: A flat loop in a uniform field.
The weber
- where
- weber, the SI unit of flux
Use it when: Checking units.
Common mistakes
- Using the angle to the plane of the loop. θ is measured from the normal; facing the field means θ = 0 and the most flux.
- Treating flux as a vector. It is a scalar: B dotted with A.
- Thinking flux is the same as field. A strong field through a tiny loop can give less flux than a weak field through a big one.
Quick check
Test yourself — pick an answer to see if you got it.
1. A loop of area 0.02 m² faces a field of 0.4 T. The flux through it is…
.
2. The same loop is turned so its normal is at 60° to the field. The flux becomes…
.
3. The flux through a loop is zero when…
Then θ = 90° and no lines pass through.
4. The SI unit of magnetic flux is…
1 Wb = 1 T m².
5. Doubling both the field and the area of a loop facing the field makes the flux…
.