Step 230 V down to 12 V for a charger and see the current go up as the voltage comes down, then step a power station up to 220 kV and watch the line losses vanish.

Interactive 3DPhysicsIntermediate7 min read

Drag to rotate · Right-drag to pan · Click, then scroll to zoom · Space play · Left arrowRight arrow step

What's happening

Formula & steps

    Your progress and quiz scores are saved on this device, and in your account once you sign up.

    Try this in the 3D model

    • In A step-down transformer, which coil carries the larger current?
    • In A step-down transformer, why is the secondary wound with thicker wire?
    • In Step-up for power lines, how much less heat is lost at 220 kV?

    Up or down

    Since VsVp=NsNp\dfrac{V_{s}}{V_{p}} = \dfrac{N_{s}}{N_{p}}:

    • a step-up transformer has more turns on the secondary, Ns>NpN_{s} > N_{p}, and raises the voltage;
    • a step-down transformer has fewer, Ns<NpN_{s} < N_{p}, and lowers it.

    Power in = power out

    An ideal transformer wastes no energy, so the power taken by the primary equals the power given by the secondary:

    VpIp=VsIs⇒IsIp=VpVs=NpNsV_{p}I_{p} = V_{s}I_{s} \quad \Rightarrow \quad \frac{I_{s}}{I_{p}} = \frac{V_{p}}{V_{s}} = \frac{N_{p}}{N_{s}}

    The currents go the other way from the voltages: stepping the voltage down steps the current up.

    A step-down transformer

    In the 3D model, choose A step-down transformer. A phone charger has 230 V across a primary of 1150 turns and a secondary of only 60 turns:

    Vs=230×601150=12 VV_{s} = 230 \times \frac{60}{1150} = 12 \text{ V}

    The phone takes 24 W, so Is=2412=2I_{s} = \dfrac{24}{12} = 2 A, while the primary supplies only Ip=24230=0.104I_{p} = \dfrac{24}{230} = 0.104 A. The side with fewer turns carries more current, so it is wound with thicker wire.

    Step-up for power lines

    Choose Step-up for power lines. A power station sends 1 MW to a town along lines of 10 Ω.

    line voltage current heat lost in the lines
    11 kV 91 A 82.6 kW
    220 kV 4.5 A 0.21 kW

    Raising the voltage 20 times lowers the current 20 times, and the I2RI^{2}R loss 400 times. So power is stepped up to hundreds of kilovolts at the power station, sent across the country, and stepped down in stages, to 230 V for homes. This is why the grid uses AC.

    Worked example

    A transformer has 200 turns on its primary and 4000 on its secondary. The primary is on 230 V and the secondary supplies 0.5 A. Find (a) the secondary voltage, (b) the primary current, assuming no losses.

    1. (a) Vs=230×4000200=V_{s} = 230 \times \dfrac{4000}{200} = 4600 V, a step-up transformer.
    2. (b) Ip=IsNsNp=0.5×20=I_{p} = I_{s}\dfrac{N_{s}}{N_{p}} = 0.5 \times 20 = 10 A. Check: 230×10=4600×0.5=2300230 \times 10 = 4600 \times 0.5 = 2300 W.

    Remember: step-up: Ns>NpN_{s} > N_{p}; step-down: Ns<NpN_{s} < N_{p}; power in = power out, so Is/Ip=Np/NsI_{s}/I_{p} = N_{p}/N_{s}; power is sent at high voltage and low current to cut the I2RI^{2}R loss.

    Formulas and where to use them

    Voltages

    VsVp=NsNp\frac{V_{s}}{V_{p}} = \frac{N_{s}}{N_{p}}
    where
    Ns>NpN_{s} > N_{p}
    step-up
    Ns<NpN_{s} < N_{p}
    step-down

    Use it when: Any transformer.

    Currents

    VpIp=VsIs,IsIp=NpNsV_{p}I_{p} = V_{s}I_{s}, \qquad \frac{I_{s}}{I_{p}} = \frac{N_{p}}{N_{s}}
    where
    Ip, IsI_{p},\ I_{s}
    primary and secondary currents

    Use it when: An ideal transformer: power in = power out.

    Common mistakes

    • Thinking a step-up transformer increases power. It raises the voltage and lowers the current by the same ratio.
    • Getting the current ratio upside down. The coil with fewer turns carries more current.
    • Thinking high-voltage lines carry big currents. High voltage means low current, which is the whole point.

    Quick check

    Test yourself — pick an answer to see if you got it.

    1. A step-down transformer has…

    2. 230 V on 1150 turns, with 60 turns on the secondary, gives…

    3. An ideal transformer gives 2 A at 12 V. The primary current from 230 V is about…

    4. Raising the transmission voltage 20 times cuts the I²R loss in the line by a factor of…

    5. Np = 200 and Ns = 4000 on 230 V. If the secondary carries 0.5 A, the primary carries…