Where the energy goes
An ideal transformer would give out every watt it takes in. A real one does not. In the 3D model, choose Where the energy goes and press Play. A transformer takes 1000 W:
- Copper loss: 20 W. The windings have resistance, and the currents heat them, .
- Eddy-current loss: 10 W. The changing flux drives currents round inside the iron core, heating it.
- Hysteresis loss: 10 W. Fifty times a second the core is magnetised one way and then the other; each cycle wastes the energy of its hysteresis loop.
- Flux leakage: 10 W. A little of the primary’s flux strays outside the core and misses the secondary.
The output is 950 W, an efficiency of
Most of the lost energy becomes heat, which is why large transformers are cooled by oil and fins.
Cutting the losses
Choose Cutting the losses.
| loss | how it is cut | here |
|---|---|---|
| copper | thick copper wire of low resistance | 20 → 5 W |
| eddy currents | a core of thin insulated sheets (laminated) | 10 → 2 W |
| hysteresis | a core of soft iron, with a thin hysteresis loop | 10 → 2 W |
| flux leakage | the secondary wound on top of the primary | 10 → 1 W |
Output 990 W: an efficiency of 99%. Large power transformers really are this good, among the most efficient machines ever built.
Worked example
A transformer takes 2000 W from the mains and delivers 1880 W to its load. Find (a) its efficiency, (b) the power lost, (c) where that power goes.
- (a) 94%.
- (b) 120 W lost.
- (c) As heat in the windings (copper loss) and the core (eddy currents and hysteresis), plus flux that leaks away and misses the secondary.
Remember: a transformer loses energy as copper loss (thick wire), eddy currents (laminated core), hysteresis (soft iron) and flux leakage (coils wound together); efficiency = output ÷ input, up to 99%.
Formulas and where to use them
Efficiency
- where
- efficiency
- output and input power (W)
Use it when: Any real transformer; large ones reach 99%.
Copper loss
- where
- resistance of a winding (Ω)
Use it when: Heating of the primary and secondary coils.
Common mistakes
- Thinking laminating stops the flux. It only breaks up the eddy currents; the flux still passes along the sheets.
- Confusing hysteresis with eddy currents. Hysteresis is the energy of magnetising the iron back and forth; eddy currents are currents in it.
- Expecting 100% efficiency. Every real transformer loses some energy, mostly as heat.
Quick check
Test yourself — pick an answer to see if you got it.
1. The loss due to the resistance of the windings is called…
I²R heating of the copper.
2. Eddy-current loss is reduced by…
Thin insulated sheets break up the eddy currents.
3. Hysteresis loss is reduced by making the core of…
Soft iron has a thin hysteresis loop.
4. A transformer takes 2000 W and gives 1880 W. Its efficiency is…
.
5. Flux leakage is reduced by…
Then nearly all the flux links both coils.