1. Home
  2. Class 11–12
  3. Physics
  4. Maharashtra Board Class 12
  5. Magnetic Susceptibility

Magnetic Susceptibility

Put aluminium and bismuth rods in a solenoid and watch their tiny magnetisations grow in step with H. Then line up materials from water to mu-metal on a ladder of χ.

Interactive 3DPhysicsIntermediate6 min read

Drag to rotate · Right-drag to pan · Click, then scroll to zoom · Space play · Left arrowRight arrow step

What's happening

Formula & steps

    Your progress and quiz scores are saved on this device, and in your account once you sign up.

    Try this in the 3D model

    • In M grows with H, what happens to M when H is doubled?
    • In M grows with H, why is bismuth’s line below the H axis?
    • In A ladder of χ, how many times bigger is iron’s χ than aluminium’s?

    How easily is it magnetised?

    Put a material in a magnetising field H and it becomes magnetised, with magnetisation M. For many materials M is proportional to H. The ratio is the magnetic susceptibility:

    χ=MH\chi = \frac{M}{H}

    M and H are both in A/m, so χ is a pure number.

    M grows with H

    In the 3D model, choose M grows with H and press Play. A rod in a solenoid is magnetised as the current, and H, increase:

    H (A/m) M, aluminium M, bismuth
    1000 +0.022 A/m −0.166 A/m
    2000 +0.044 A/m −0.332 A/m
    3000 +0.066 A/m −0.498 A/m

    Both are straight lines through the origin. Aluminium is magnetised along H: χ = +2.2 × 10⁻⁵, paramagnetic. Bismuth is magnetised against H: χ = −1.66 × 10⁻⁴, diamagnetic. A soft-iron rod, χ ≈ 5000, would be magnetised to about 1.5 × 10⁷ A/m.

    A ladder of χ

    Choose A ladder of χ.

    material χ kind
    water −9.0 × 10⁻⁶ diamagnetic
    copper −9.6 × 10⁻⁶ diamagnetic
    bismuth −1.66 × 10⁻⁴ diamagnetic
    oxygen gas +1.9 × 10⁻⁶ paramagnetic
    aluminium +2.2 × 10⁻⁵ paramagnetic
    platinum +2.7 × 10⁻⁴ paramagnetic
    nickel about 600 ferromagnetic
    soft iron about 5000 ferromagnetic
    mu-metal about 50 000 ferromagnetic
    • Diamagnetic: χ small and negative.
    • Paramagnetic: χ small and positive.
    • Ferromagnetic: χ large and positive, and not constant: it depends on H and on what has been done to the material before.

    Temperature

    Heat jostles the atomic magnets of a paramagnet out of line, so its susceptibility falls as temperature rises (Curie’s law):

    χ=CT\chi = \frac{C}{T}

    Diamagnetic χ hardly depends on temperature. A ferromagnet heated above its Curie temperature (770 °C for iron) becomes paramagnetic.

    Worked example

    An aluminium rod (χ = 2.2 × 10⁻⁵) lies in a solenoid where H = 4000 A/m. Find its magnetisation. A paramagnetic salt has χ = 2.0 × 10⁻⁴ at 300 K; what is χ at 150 K?

    1. M=χH=2.2×10−5×4000=M = \chi H = 2.2 \times 10^{-5} \times 4000 = 0.088 A/m.
    2. Curie’s law, χ∝1/T\chi \propto 1/T: half the temperature, so χ = 4.0 × 10⁻⁴.

    Remember: χ=M/H\chi = M/H, a pure number: small and negative for diamagnets, small and positive for paramagnets, large for ferromagnets.

    Formulas and where to use them

    Magnetic susceptibility

    χ=MH\chi = \dfrac{M}{H}
    where
    MM
    magnetisation (A/m)
    HH
    magnetising field (A/m)

    Use it when: A pure number with no unit.

    Curie's law

    χ=CT\chi = \dfrac{C}{T}
    where
    CC
    Curie constant of the material
    TT
    absolute temperature (K)

    Use it when: Paramagnetic materials.

    Common mistakes

    • Giving χ a unit. M and H are both in A/m, so χ has none.
    • Thinking a negative χ means no magnetism. It means the material is magnetised against the field: diamagnetism.
    • Using one χ for iron. For ferromagnets χ depends on H and on the material’s history.

    Quick check

    Test yourself — pick an answer to see if you got it.

    1. Magnetic susceptibility is defined as…

    2. A material has χ = −1.66 × 10⁻⁴. It is…

    3. An aluminium rod (χ = 2.2 × 10⁻⁵) is in a field H = 4000 A/m. Its magnetisation is…

    4. A paramagnetic salt has χ = 2.0 × 10⁻⁴ at 300 K. At 150 K it is…

    5. Which has the largest susceptibility?

    Saved on this device.
    Spotted a mistake or a bug in the 3D model?

    Report a mistake

    in Magnetic Susceptibility. Thank you — every report makes the lesson better for the next reader.

    We'll also include a link to the step of the 3D model you're on and your browser type, so we can reproduce it.