Heat stirs the atomic magnets
Heat makes atoms jostle, and jostling atoms cannot line up their tiny magnets so well. So temperature changes how strongly a material is magnetised, in a different way for each kind of material.
Paramagnets: Curie’s law
In the 3D model, choose Warming a paramagnet and press Play. A paramagnet sits in a steady field.
- At 50 K the jostling is small, so many atomic magnets lean along the field: χ is large.
- Warm it, and they line up less and less.
The susceptibility falls as 1/T. This is Curie’s law:
where C is the Curie constant of the material and T is in kelvin. (Some books write it as , with C defined a little differently; either way, χ goes as 1/T.) Here χ is at 300 K: doubling the temperature from 150 K to 300 K halves χ. Since and , the magnetisation goes as : a stronger field or a colder sample, more magnetisation.
Ferromagnets: the Curie temperature
Choose The Curie temperature. Inside one domain of iron at room temperature, the atomic magnets are all lined up by themselves. Heat it:
- the domain’s magnetisation falls, slowly at first, then faster;
- at 1043 K (770 °C), the Curie temperature , the order breaks up completely. There are no more domains.
Above iron is only paramagnetic, with
Cool it again, and the domains come back.
| material | Curie temperature |
|---|---|
| iron | 1043 K (770 °C) |
| nickel | 631 K (358 °C) |
| cobalt | 1394 K (1121 °C) |
| gadolinium | 293 K (20 °C) |
Gadolinium is ferromagnetic only on a cool day.
Diamagnets
A diamagnet’s moments are made by the field itself, in each atom, so the jostling of heat hardly matters. Its χ stays almost the same at any temperature.
Worked example
A paramagnetic sample has a magnetisation of 12 A/m in a field of 0.5 T at 5 K. Find its magnetisation in a field of 0.25 T at 10 K.
- Curie’s law: .
- 3 A/m.
Remember: paramagnets obey Curie’s law, with T in kelvin; a ferromagnet loses its domains at its Curie temperature and becomes paramagnetic, ; diamagnets hardly change.
Formulas and where to use them
Curie’s law
- where
- Curie constant of the material (K)
- temperature (K)
- applied field (T)
Use it when: A paramagnet, not too cold and not too strong a field.
Above the Curie temperature
- where
- Curie temperature of the ferromagnet (K)
Use it when: A ferromagnet heated above its Curie temperature, now paramagnetic.
Common mistakes
- Using degrees Celsius. Curie’s law needs the temperature in kelvin.
- Thinking a hot magnet loses its magnetism gradually forever. Below Tc it weakens slowly; at Tc the domains vanish completely.
- Applying Curie’s law to diamagnets. Their χ hardly changes with temperature.
Quick check
Test yourself — pick an answer to see if you got it.
1. A paramagnet has χ = 2.4 × 10⁻⁴ at 300 K. At 200 K its χ is…
: .
2. Above its Curie temperature, a ferromagnet becomes…
Its domains break up.
3. The Curie temperature of iron is about…
That is 770 °C.
4. The susceptibility of a diamagnet, when it is heated…
Its induced moments do not depend on thermal jostling.
5. A paramagnet has M = 12 A/m in 0.5 T at 5 K. In 0.25 T at 10 K its magnetisation is…
: half the field and twice the temperature.