  3. Hardwired vs Microprogrammed Control Unit

Hardwired vs Microprogrammed Control Unit

How the CPU turns each instruction into control signals, one clock step at a time. Run the same program on a hardwired control unit (logic gates) and a microprogrammed one (a control memory) in 3D.

Interactive 3DIntermediate14 min readCOAUpdated

Drag to rotate · Right-drag to pan · Click, then scroll to zoom · Space play · ←→ step

What's happening

Pseudocode

    Try this in the 3D model

    • Run the program with Hardwired. At step T1, which two signals are on, and which equation switches READ on?
    • Switch to Microprogrammed and run again. Which control-memory address comes after fetching LOAD 6, and why that one?
    • Count the clock steps of each instruction. Why does JUMP need fewer than ADD?
    • Set M[6] = 40 and M[7] = 2. Where does the answer end up?

    The CPU’s conductor

    A CPU has two halves:

    • The datapath: registers (PC, MAR, MDR, IR, AC), the ALU, and the paths between them. It can move and combine data, but it doesn’t decide anything on its own.
    • The control unit: on every clock tick it switches on a few control signals, such as “copy PC into MAR” or “read memory”, which tell the datapath what to do in that step.

    A single register transfer like MAR ← PC is called a micro-operation. Every machine instruction is a short sequence of them.

    One instruction = a few micro-operations

    The model’s CPU has an accumulator (AC) and four instructions. Every instruction starts with the same three-step fetch:

    Step Micro-operation Control signals
    T0 MAR ← PC PC→MAR
    T1 MDR ← M[MAR], PC ← PC + 1 READ, PC+1
    T2 IR ← MDR MDR→IR

    Then the execute steps depend on the opcode:

    Instruction T3 T4 T5
    LOAD X MAR ← X MDR ← M[MAR] AC ← MDR
    ADD X MAR ← X MDR ← M[MAR] AC ← AC + MDR
    STORE X MAR ← X MDR ← AC M[MAR] ← MDR
    JUMP X PC ← X

    The control unit’s whole job is to produce the right signals at the right step. There are two classic ways to build it.

    Hardwired control

    A hardwired control unit is a fixed logic circuit:

    1. A step counter with a decoder gives one line per step: T0, T1, … T5.
    2. An instruction decoder turns the opcode in IR into one line per instruction: ADD, LOAD, STORE, JUMP.
    3. AND/OR gates combine them into each control signal:
    Signal Equation
    PC→MAR T0
    READ T1 + T4·(ADD + LOAD)
    PC+1 T1
    MDR→IR T2
    IR→MAR T3·(ADD + LOAD + STORE)
    ADD T5·ADD
    MDR→AC T5·LOAD
    AC→MDR T4·STORE
    WRITE T5·STORE
    IR→PC T3·JUMP

    On the last step of an instruction (T5, or T3 for JUMP) the step counter is cleared so the next fetch starts at T0.

    Microprogrammed control

    A microprogrammed control unit stores the signals instead of computing them. Each row of a small control memory (ROM) is a control word (micro-instruction): one bit per signal plus the address of the next word.

    Address Signals on Next
    0 PC→MAR 1
    1 READ, PC+1 2
    2 MDR→IR map
    4–6 ADD: IR→MAR · READ · ADD 0
    8–10 LOAD: IR→MAR · READ · MDR→AC 0
    12–14 STORE: IR→MAR · AC→MDR · WRITE 0
    16 JUMP: IR→PC 0

    The control address register (CAR) points at the current word. Each clock step:

    1. Read the word at CAR and switch on its signals.
    2. Load the next address into CAR. When it says map, mapping logic turns the opcode into the routine’s start address: here 4 × (opcode + 1).

    The words in the model have one bit per signal, which is called horizontal microcode: fast, and several signals can be on at once, but the words are wide. Vertical microcode encodes the signals in short fields that a decoder expands. The words are smaller, but there is an extra decoding delay.

    Side by side

    Hardwired Microprogrammed
    Built from logic gates control memory + sequencer
    Speed faster slower: one control-memory read per step
    Adding or fixing an instruction redesign the circuit rewrite words in the control memory
    Many complex instructions very hard to design manageable
    Typical use RISC processors (MIPS, ARM, RISC-V) classic CISC processors (IBM System/360, older x86)

    Modern x86 chips mix both. Common instructions are decoded by fast hardwired logic, while rare complex ones run from a microcode ROM. Because microcode can be patched, CPU makers can ship microcode updates to fix bugs after a chip is sold.

    Code

    mem = {0: ('LOAD', 6), 1: ('ADD', 7), 2: ('STORE', 8), 3: ('JUMP', 0), 6: 25, 7: 17, 8: 0}
    OPCODE = {'ADD': 0, 'LOAD': 1, 'STORE': 2, 'JUMP': 3}
    
    # Microprogrammed: address -> (signals that are on, next address)
    control_memory = {
        0: ({'PC->MAR'}, 1),    1: ({'READ', 'PC+1'}, 2),  2: ({'MDR->IR'}, 'map'),
        4: ({'IR->MAR'}, 5),    5: ({'READ'}, 6),          6: ({'ADD'}, 0),        # ADD
        8: ({'IR->MAR'}, 9),    9: ({'READ'}, 10),        10: ({'MDR->AC'}, 0),    # LOAD
        12: ({'IR->MAR'}, 13), 13: ({'AC->MDR'}, 14),     14: ({'WRITE'}, 0),      # STORE
        16: ({'IR->PC'}, 0),                                                       # JUMP
    }
    
    # Hardwired: the same signals as gate equations of the step T and the opcode
    def hardwired(t, op):
        eq = {
            'PC->MAR': t == 0,
            'READ':    t == 1 or (t == 4 and op in ('ADD', 'LOAD')),
            'PC+1':    t == 1,
            'MDR->IR': t == 2,
            'IR->MAR': t == 3 and op in ('ADD', 'LOAD', 'STORE'),
            'ADD':     t == 5 and op == 'ADD',
            'MDR->AC': t == 5 and op == 'LOAD',
            'AC->MDR': t == 4 and op == 'STORE',
            'WRITE':   t == 5 and op == 'STORE',
            'IR->PC':  t == 3 and op == 'JUMP',
        }
        return {s for s, on in eq.items() if on}
    
    def step(signals, r):
        """Do the register transfers for one clock step."""
        if 'PC->MAR' in signals: r['MAR'] = r['PC']
        if 'IR->MAR' in signals: r['MAR'] = r['IR'][1]
        if 'IR->PC'  in signals: r['PC'] = r['IR'][1]
        if 'READ'    in signals: r['MDR'] = mem[r['MAR']]
        if 'PC+1'    in signals: r['PC'] += 1
        if 'MDR->IR' in signals: r['IR'] = r['MDR']
        if 'ADD'     in signals: r['AC'] += r['MDR']
        if 'MDR->AC' in signals: r['AC'] = r['MDR']
        if 'AC->MDR' in signals: r['MDR'] = r['AC']
        if 'WRITE'   in signals: mem[r['MAR']] = r['MDR']
    
    r = {'PC': 0, 'MAR': 0, 'MDR': 0, 'IR': None, 'AC': 0}
    car, t, done = 0, 0, 0
    while done < 4:                                   # run the 4 instructions once
        signals, nxt = control_memory[car]
        op = r['IR'][0] if t >= 3 else None
        assert signals == hardwired(t, op)            # both control units agree
        step(signals, r)
        if nxt == 'map':
            nxt = 4 * (OPCODE[r['IR'][0]] + 1)        # mapping logic
        t = 0 if nxt == 0 else t + 1
        done += nxt == 0
        car = nxt
    
    print(r['AC'], mem[8])    # 42 42

    Common mistakes

    • Mixing up the program and the microprogram. The program (LOAD 6, ADD 7, …) lives in main memory and is written by programmers. The microprogram lives in control memory inside the CPU and says how to carry out each instruction.
    • Calling microcode software. It is firmware stored in ROM inside the CPU, and the user program can’t change it.
    • Forgetting the shared fetch. T0 to T2 (control words 0 to 2) are the same for every instruction. Only the execute steps differ.
    • Forgetting that the PC moves during the fetch. After T1 the PC already points to the next instruction, which is why a JUMP has to overwrite it.

    Complexity at a glance

    Case / operationTimeWhy
    Fetch (every instruction)3 clock stepsT0 MAR ← PC, T1 MDR ← M[MAR] and PC ← PC + 1, T2 IR ← MDR.
    LOAD, ADD, STORE6 clock steps3 to fetch + 3 to execute.
    JUMP4 clock steps
    One microprogrammed step1 control-memory readHardwired gates answer in a few gate delays, which is faster.
    Extra spaceControl memory: 13 words × (10 signal bits + next address)

    Quick check

    Test yourself — pick an answer to see if you got it.

    1. What does the control memory of a microprogrammed control unit hold?

    2. What is the main advantage of a hardwired control unit?

    3. In the model READ = T1 + T4·(ADD + LOAD). During which steps of a STORE instruction is READ on?

    4. After fetching an instruction, how does a microprogrammed control unit find the routine for its opcode?

    5. Why did classic CISC processors use microprogrammed control?

    Saved in this browser.