What the power factor is
In , the factor is the power factor. It says what fraction of is really used. From the impedance triangle,
- pure resistor: φ = 0, cos φ = 1;
- pure inductor or capacitor: φ = ±90°, cos φ = 0;
- anything in between: a power factor between 0 and 1.
The triangle tilts
In the 3D model, choose cos φ = R/Z and press Play. A resistance of 60 Ω on 230 V rms, with growing reactance X:
| X | Z | cos φ | P |
|---|---|---|---|
| 0 | 60 Ω | 1 | 882 W |
| 40 Ω | 72 Ω | 0.83 | 610 W |
| 80 Ω | 100 Ω | 0.6 | 317 W |
As the reactance grows, the triangle tilts up, φ grows and cos φ falls. Less current flows, and less of it is in step with the voltage.
Why it matters
Choose Why it matters. A factory’s motors need 920 W from 230 V, with a power factor of 0.8:
The supply cables, 2 Ω in all, waste W. Capacitors across the supply cancel the motors’ inductive reactance and bring the power factor up to 1. The same 920 W then needs only 4 A, and the cables waste just 32 W.
A low power factor means a bigger current for the same useful power, and bigger currents waste more energy heating the cables. That is why supply companies ask large users to keep their power factor close to 1.
Worked example
A circuit with R = 60 Ω has an impedance of 100 Ω on 230 V rms mains. Find (a) the power factor, (b) the current, (c) the average power.
- (a) 0.6.
- (b) 2.3 A.
- (c) 317 W (the same as ).
Remember: power factor , 1 for R and 0 for pure L or C; a low power factor needs more current for the same power and wastes more in the cables; capacitors are added to raise it.
Formulas and where to use them
Power factor
- where
- resistance (Ω)
- impedance (Ω)
Use it when: Any AC circuit; between 0 and 1.
Current for a given power
- where
- power needed (W)
Use it when: A load drawing power P from a supply.
Common mistakes
- Thinking a power factor of 0.5 means half the current. It means only half of V × I is real power; the current may be large.
- Thinking reactance wastes power. The waste comes from the larger current heating the cables.
- Giving a power factor above 1. cos φ can never exceed 1.
Quick check
Test yourself — pick an answer to see if you got it.
1. The power factor of a pure resistor is…
φ = 0.
2. R = 60 Ω and Z = 100 Ω. The power factor is…
.
3. A load needs 920 W from 230 V with a power factor of 0.8. It draws…
.
4. A low power factor is bad for a supply company because…
Cable loss goes as I²R.
5. The power factor of an inductive load, like a motor, is improved by adding…
It cancels the inductive reactance.