1. Home
  2. Class 11–12
  3. Physics
  4. CBSE Class 12
  5. Moving Coil Galvanometer

Moving Coil Galvanometer

Look inside a galvanometer from above, see the radial field between curved poles, balance the magnetic torque against a spring, and make the meter more sensitive.

Interactive 3DPhysicsAdvanced7 min read

Drag to rotate · Right-drag to pan · Click, then scroll to zoom · Space play · Left arrowRight arrow step

What's happening

Formula & steps

    Your progress and quiz scores are saved on this device, and in your account once you sign up.

    Try this in the 3D model

    • In Inside the galvanometer, why are the pole pieces curved and the core round?
    • In Inside the galvanometer, what stops the coil from turning further?
    • In Sensitivity, what changes when the coil has twice as many turns?

    What is inside

    A galvanometer detects and measures small currents. In the 3D model, choose Inside the galvanometer; we look down on it from above.

    • A coil of fine wire hangs between the poles of a strong magnet, round a soft-iron core.
    • The pole pieces are curved and the core is round, so the field is radial: it points along the radius everywhere in the gap, and so always lies in the plane of the coil.
    • A spring holds the coil and twists back when the coil turns. A pointer on the coil moves over a scale.

    Balancing two torques

    Press Play. A current flows, and the field turns the coil. Because the field always lies in the plane of the coil, the magnetic torque is NIABNIAB at every angle. The spring twists back with a torque kϕk\phi that grows as the coil turns. The coil stops where they balance:

    kϕ=NIAB⇒ϕ=(NABk)Ik\phi = NIAB \quad \Rightarrow \quad \phi = \left(\frac{NAB}{k}\right)I

    The deflection is proportional to the current, so the scale is evenly spaced. With 100 turns of area 2×10−42 \times 10^{-4} m², B = 0.25 T and k=5×10−6k = 5 \times 10^{-6} N m per radian:

    ϕI=100×2×10−4×0.255×10−6=1000 rad/A\frac{\phi}{I} = \frac{100 \times 2 \times 10^{-4} \times 0.25}{5 \times 10^{-6}} = 1000 \text{ rad/A}

    So 1 mA turns the coil by 1 rad, 57°.

    Sensitivity

    Choose Sensitivity. The current sensitivity is the deflection per unit current, ϕI=NABk\dfrac{\phi}{I} = \dfrac{NAB}{k}. Wind the coil with twice as many turns, and 0.5 mA turns it twice as far. A stronger magnet or a weaker spring does the same.

    The voltage sensitivity is the deflection per volt across the meter. Since V=IGV = IG:

    ϕV=NABkG\frac{\phi}{V} = \frac{NAB}{kG}

    With G = 50 Ω, this is 20 rad/V. But doubling the turns also doubles the length of wire, and so G: the voltage sensitivity stays the same.

    Worked example

    A galvanometer coil has 200 turns of area 1 × 10⁻⁴ m² in a radial field of 0.2 T. The spring constant is 2 × 10⁻⁶ N m/rad. Find (a) its current sensitivity, (b) the deflection for 0.1 mA.

    1. (a) ϕI=NABk=200×10−4×0.22×10−6=\dfrac{\phi}{I} = \dfrac{NAB}{k} = \dfrac{200 \times 10^{-4} \times 0.2}{2 \times 10^{-6}} = 2000 rad/A.
    2. (b) ϕ=2000×10−4=0.2\phi = 2000 \times 10^{-4} = 0.2 rad == 11.5°.

    Remember: in a radial field the torque is NIAB at every angle; the spring balances it, kϕ=NIABk\phi = NIAB, so the deflection is proportional to the current; current sensitivity is NAB/kNAB/k.

    Formulas and where to use them

    Balance of torques

    kϕ=NIAB⇒ϕ=(NABk)Ik\phi = NIAB \quad \Rightarrow \quad \phi = \left(\frac{NAB}{k}\right)I
    where
    kk
    torsion constant of the spring (N m per radian)
    ϕ\phi
    deflection of the coil (rad)
    N, AN,\ A
    number of turns and area of the coil
    BB
    radial magnetic field (T)

    Use it when: A moving coil galvanometer at rest with a steady current.

    Current sensitivity

    ϕI=NABk\frac{\phi}{I} = \frac{NAB}{k}
    where
    ϕ/I\phi/I
    deflection per unit current (rad/A)

    Use it when: Comparing how sensitive galvanometers are.

    Voltage sensitivity

    ϕV=NABkG\frac{\phi}{V} = \frac{NAB}{kG}
    where
    GG
    resistance of the coil (Ω)

    Use it when: Deflection per volt across the galvanometer.

    Common mistakes

    • Writing τ = NIAB sin θ for a galvanometer. The field is radial, so the plane of the coil always lies along it and the torque is NIAB at every angle.
    • Thinking more turns always raises voltage sensitivity. Doubling N doubles G too, so φ/V stays the same.
    • Forgetting the spring. Without it the coil would turn as far as it could; the spring makes the deflection measure the current.

    Quick check

    Test yourself — pick an answer to see if you got it.

    1. The pole pieces of a galvanometer are curved and the core is round so that…

    2. At rest, the deflection φ of a galvanometer coil is given by…

    3. N = 100, A = 2 × 10⁻⁴ m², B = 0.25 T, k = 5 × 10⁻⁶ N m/rad. The current sensitivity is…

    4. Doubling the turns of a galvanometer coil (and so its resistance) makes the voltage sensitivity…

    5. The scale of a moving coil galvanometer is even because…

    Saved on this device.
    Spotted a mistake or a bug in the 3D model?

    Report a mistake

    in Moving Coil Galvanometer. Thank you — every report makes the lesson better for the next reader.

    We'll also include a link to the step of the 3D model you're on and your browser type, so we can reproduce it.