Magnetisation
In the 3D model, choose Moment per unit volume. A bar of iron, 5 cm × 1 cm × 1 cm ( m³), has its atomic magnets pointing every which way: their moments cancel. As it is magnetised they line up, and the net moment grows to 4 A m².
The magnetisation is the net moment per unit volume:
Its unit is A m² / m³ = A/m. A bigger bar of the same iron, magnetised the same way, has a bigger moment but the same M: M describes the material, not the size.
Magnetic intensity
Choose A core in a solenoid. A long solenoid with turns per metre carries A. The currents set up a magnetic intensity
whatever is put inside. Empty, the field is T, so in general .
Susceptibility
Put a material in, and it becomes magnetised. For most materials M is proportional to H:
where χ is the magnetic susceptibility, a pure number. The field inside is then
with the relative permeability. Watch the cores go in:
| Core | χ | M (A/m) | B (T) |
|---|---|---|---|
| none | 0 | 0 | 2.5133 × 10⁻⁴ |
| aluminium (para) | 2.3 × 10⁻⁵ | 4.6 × 10⁻³ | a hair bigger |
| bismuth (dia) | −1.66 × 10⁻⁵ | −3.3 × 10⁻³ (against H) | a hair smaller |
| iron (ferro) | about 1000 | 2 × 10⁵ | 0.25 |
Iron multiplies the field about a thousand times: that is why electromagnets, motors and transformers have iron cores. Other values of χ: copper , oxygen gas .
M against H
Choose M against H. For dia and para materials M grows in proportion to H: straight lines, sloping down (χ < 0) or up (χ > 0). For iron, M shoots up and then levels off: once all its domains are lined up it is saturated. So for a ferromagnet χ is not a constant.
Worked example
A long solenoid of 800 turns per metre carries 1.5 A. A rod with χ = 599 fills it. Find H, M, B and μr.
- A/m.
- A/m.
- .
- 0.90 T.
Remember: (A/m); (A/m) is set by the currents; , and .
Formulas and where to use them
Magnetisation
- where
- net magnetic moment (A m²)
- volume (m³)
- magnetisation (A/m)
Use it when: Describing how strongly a piece of material is magnetised.
Magnetic intensity
- where
- field the currents make in empty space (T)
- turns per metre
- magnetic intensity (A/m)
Use it when: The magnetising field set up by currents, whatever material is present.
Susceptibility and permeability
- where
- magnetic susceptibility (no unit)
- relative permeability (no unit)
Use it when: Dia and para materials (χ constant); for ferromagnets χ depends on H.
Common mistakes
- Mixing up B and H. H is set by the currents (A/m); B is the actual field (T) and includes the material’s magnetisation.
- Giving χ a unit. M and H are both in A/m, so χ is a pure number.
- Treating iron’s χ as constant. Iron saturates: its M levels off, so χ falls at large H.
Quick check
Test yourself — pick an answer to see if you got it.
1. The SI unit of magnetisation is…
Moment (A m²) per volume (m³).
2. A solenoid has 1000 turns/m and carries 2 A. H inside is…
.
3. For a material with χ = 499, μr is…
.
4. A material has negative susceptibility. It is…
M is opposite to H.