The hysteresis loop
In a ferromagnet, B depends not only on H but on what has been done to the material before. Take a piece of iron round a full cycle of magnetisation and plot B against H.
In the 3D model, choose Round the loop and press Play. The bar on the left shows the iron’s domains, magnetised one way or the other.
| point | what happens |
|---|---|
| O → a | domains swing into line; B rises to saturation |
| a → b | H back to zero; B stays at the retentivity |
| b → c | H reversed; B reaches zero at , the coercivity |
| c → d | saturation the other way |
| d → e → f | back through , and zero again at |
| f → a | to saturation again |
B always lags behind H: hysteresis (Greek for “lagging behind”). The closed curve abca… is the hysteresis loop.
Energy loss
Each time the domains are swung round, some energy turns into heat. The energy lost per cycle per unit volume equals the area of the B–H loop. A transformer core is taken round its loop 50 times a second, so its loop must be narrow.
Soft iron and steel
Choose Soft iron and steel.
| soft iron | steel, alnico, NdFeB | |
|---|---|---|
| loop | tall and narrow | wide |
| retentivity | fairly high | high |
| coercivity | low: easy to demagnetise | high: hard to demagnetise |
| loss per cycle | small | large |
| used for | electromagnets, transformer and motor cores, relays | permanent magnets: motors, speakers, fridge doors |
An electromagnet must lose its magnetism when the current stops, and a core must waste little energy, so they need soft materials. A permanent magnet must keep its magnetism and resist stray fields, so it needs hard materials.
Worked example
The hysteresis loop of a transformer core encloses 250 J/m³. The core has a volume of 1.0 × 10⁻³ m³ and works at 50 Hz. How much power is lost as heat by hysteresis?
- Energy per cycle: J.
- Power: 12.5 W.
Remember: retentivity is the B left at H = 0; coercivity is the reverse H that removes it; loop area = energy lost per cycle; soft iron for cores and electromagnets, hard steel for permanent magnets.
Formulas and where to use them
Energy lost per cycle
- where
- volume of the material (m³)
Use it when: Turned into heat every cycle.
Power lost in an alternating field
- where
- number of cycles per second (Hz)
Use it when: Transformer and motor cores.
Common mistakes
- Thinking B returns to zero with H. In a ferromagnet some magnetisation remains: the retentivity.
- Confusing retentivity and coercivity. Retentivity is a field B left over; coercivity is the reverse H needed to remove it.
- Using steel for a transformer core. Its wide loop would waste energy as heat every cycle.
Quick check
Test yourself — pick an answer to see if you got it.
1. The value of B left when H is reduced to zero is the…
Also called remanence.
2. The reverse magnetising field needed to make B zero is the…
Point c on the loop.
3. The energy lost as heat per cycle per unit volume equals…
That is why cores need narrow loops.
4. A good material for a permanent magnet has…
It must keep its magnetism and resist losing it.
5. Soft iron is used for transformer cores because it has…
It is magnetised back and forth 50 times a second.