Parts of a circuit
A circuit needs a source (cell, battery, mains), connecting wires, a switch to open and close it, and the load (bulb, motor, heater). Meters measure it: an ammeter in series, a voltmeter in parallel. Circuit diagrams use standard symbols for each part, with arrows showing conventional current.
House wiring
In the 3D model, choose Appliances in parallel. The mains supply arrives as:
- a live wire (red), at 230 V;
- a neutral wire (blue), at about 0 V;
- an earth wire (green), connected to a metal plate buried in the ground.
Appliances are connected in parallel between live and neutral, each with its switch in the live wire. So each gets the full 230 V and can be switched on and off without affecting the others. The main current is the sum of their currents:
| Switched on | Main current |
|---|---|
| 60 W bulb | 0.26 A |
| + 75 W fan | 0.59 A |
| + 1000 W iron | 4.93 A |
| + 2000 W heater | 13.6 A |
Safety devices
- Overload: too many appliances at once draw more current than the wiring can safely carry. A fuse or miniature circuit breaker (MCB) in the live wire cuts the supply.
- Short circuit: live and neutral touch directly, the resistance is almost zero and the current huge; the fuse or MCB cuts it.
- Earthing: choose Earthing and a fault. Metal-bodied appliances (iron, heater, fridge) have their case joined to the earth wire. If the live wire touches the case, a large current flows to earth and blows the fuse, so the case never stays live. Without the earth wire, the current would flow through whoever touched it.
Worked example
A kitchen circuit has a 15 A MCB at 230 V. Can a 2000 W heater, a 1500 W microwave and a 750 W mixer run together?
- Total power: W.
- Current: A, more than 15 A: no, the MCB would trip.
Remember: houses are wired in parallel (230 V to each appliance) with switches and fuses in the live wire; currents add; earthing and fuses or MCBs guard against faults, overloads and short circuits.
Formulas and where to use them
Main current
- where
- power ratings of the appliances that are on
- mains voltage, 230 V
Use it when: Choosing the rating of a fuse or circuit breaker.
Common mistakes
- Putting the switch or fuse in the neutral wire. The appliance would stay live even when switched off.
- Thinking appliances in a house are in series. They are in parallel, so each gets 230 V.
- Replacing a fuse with a higher rating. It may not blow before the wiring overheats.
Quick check
Test yourself — pick an answer to see if you got it.
1. Household appliances are connected…
Each gets the full voltage and works on its own.
2. Switches are placed in the…
So the appliance is dead when switched off.
3. A 1000 W iron and a 2000 W heater run on 230 V. The main current is about…
A.
4. The earth wire protects you when…
The fault current flows to earth and blows the fuse.
5. A short circuit happens when…
The resistance becomes tiny and the current huge.